{"title":"Reactive power regulators","description":"\u003cp\u003e\u003c\/p\u003e","products":[{"product_id":"rgt-mt18-контролер-на-реактивната-мощност-18-нива-tcr-с-rs485-modbus","title":"RGT-MT18 - Reactive Power Controller 18 Levels +TCR with RS485 ModBus","description":"\u003cp\u003e\u003cstrong\u003e18 steps + TCR Power factor controller for symmetrical\/asymmetrical networks with 5-inch touchscreen and RS-485 (TENSE)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eThe relays for reactive power control are designed to reduce reactive power (inductive and capacitive) that is not used by the load and is drawn from the grid. When inductive power is drawn from the grid, it intervenes by removing a capacitor of appropriate value. If capacitive power is drawn from the grid, it intervenes by removing a shunt inductor of appropriate value. In this way, it attempts to reduce the inductive\/active and capacitive\/active speeds of the system. It is designed to provide more reasonable compensation in unbalanced inductive and capacitive systems with step RGT-MT18 TCR \u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp\u003eGenerator input and generator compensation\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eAlarm output for voltage, harmonic current\/voltage, inductive and capacitive current\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eAbility to adjust the activation, discharge, and settling times\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eRemote communication with RS485 (RS485 ModBus RTU)\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eSingle-phase, two-phase, and three-phase capacitors and shunt reactors can be connected\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eHarmonic voltage and current up to the 61st harmonic can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eTotal energy (import\/export) can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eThe values of THD-V and THD-I for each phase can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eCreating a power analysis (20 samples 9999 min.) - for capacitor selection\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eTemperature alarm output\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eRecording of consumption (active, reactive, and apparent power and current consumption)\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eMinimum, maximum, and average values of current and voltage for each phase can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eCurrent date and time\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":56080503308662,"sku":"RGT-MT18","price":334.08,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/4130\/7766\/files\/29021cc84c53911daf6559abe27a8950_512ef6e4-e1f3-4f49-869e-62824a55d350.png?v=1754945124"},{"product_id":"rgt-12e-регулатор-на-реактивната-мощност-12-нива-tcr","title":"RGT-12E - Reactive Power Regulator 12 Levels +TCR","description":"\u003ch1 data-start=\"175\" data-end=\"262\"\u003e\u003cstrong data-start=\"177\" data-end=\"262\"\u003e\u003cfont style=\"font-size: 18px;\"\u003ePower factor controller 12 steps + TCR with 2.9\" graphical LCD display (TENSE) - RGT-12E\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h1\u003e\u003cp data-start=\"264\" data-end=\"618\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe reactive power controller \u003cstrong data-start=\"290\" data-end=\"301\"\u003eRGT-12E\u003c\/strong\u003e from \u003cstrong data-start=\"317\" data-end=\"326\"\u003eTENSE\u003c\/strong\u003e is a fully automatic and high-precision controller designed for optimal management of compensation stages in power systems. With digital measurement, intelligent algorithms, and a graphical LCD display, it provides a stable power factor, efficient reactive power control, and protection of compensation equipment.\u003c\/font\u003e\u003c\/p\u003e\u003ch2 data-start=\"625\" data-end=\"658\"\u003e\u003cstrong data-start=\"628\" data-end=\"658\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMain features and functions\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\u003ch3 data-start=\"660\" data-end=\"708\"\u003e\u003cstrong data-start=\"664\" data-end=\"708\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAutomatic recognition of compensation stages\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\u003cp data-start=\"709\" data-end=\"753\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe controller configures itself after power-up:\u003c\/font\u003e\u003c\/p\u003e\u003cul data-start=\"754\" data-end=\"917\"\u003e\n\u003cli data-start=\"754\" data-end=\"823\"\u003e\n\u003cp data-start=\"756\" data-end=\"823\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAutomatically detects the size of connected capacitor steps\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"824\" data-end=\"863\"\u003e\n\u003cp data-start=\"826\" data-end=\"863\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eManual parameter input is also possible\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"864\" data-end=\"917\"\u003e\n\u003cp data-start=\"866\" data-end=\"917\"\u003e\u003cfont style=\"font-size: 14px;\"\u003ethe system continuously monitors the status of each step\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 data-start=\"919\" data-end=\"954\"\u003e\u003cstrong data-start=\"923\" data-end=\"954\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIntelligent switching control\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\u003cp data-start=\"955\" data-end=\"998\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe controller switches the steps on and off so that:\u003c\/font\u003e\u003c\/p\u003e\u003cul data-start=\"999\" data-end=\"1283\"\u003e\n\u003cli data-start=\"999\" data-end=\"1063\"\u003e\n\u003cp data-start=\"1001\" data-end=\"1063\"\u003e\u003cfont style=\"font-size: 14px;\"\u003ea stable power factor is achieved with a minimal number of switchings\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1064\" data-end=\"1112\"\u003e\n\u003cp data-start=\"1066\" data-end=\"1112\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eindividual steps are loaded evenly\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1113\" data-end=\"1178\"\u003e\n\u003cp data-start=\"1115\" data-end=\"1178\"\u003e\u003cfont style=\"font-size: 14px;\"\u003ecapacitors with the lowest residual charge are preferred\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1179\" data-end=\"1283\"\u003e\n\u003cp data-start=\"1181\" data-end=\"1283\"\u003e\u003cfont style=\"font-size: 14px;\"\u003ethe status of each step is checked simultaneously (faults, power changes, removal and re-engagement)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 data-start=\"1285\" data-end=\"1333\"\u003e\u003cstrong data-start=\"1289\" data-end=\"1333\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eSupport for TCR (thyristor-controlled reactor)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\u003cp data-start=\"1334\" data-end=\"1418\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe controller enables compensation control with thyristor-switched reactors, which is ideal for:\u003c\/font\u003e\u003c\/p\u003e\u003cul data-start=\"1419\" data-end=\"1505\"\u003e\n\u003cli data-start=\"1419\" data-end=\"1442\"\u003e\n\u003cp data-start=\"1421\" data-end=\"1442\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIndustrial applications\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1443\" data-end=\"1468\"\u003e\n\u003cp data-start=\"1445\" data-end=\"1468\"\u003e\u003cfont style=\"font-size: 14px;\"\u003edynamic compensation\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1469\" data-end=\"1505\"\u003e\n\u003cp data-start=\"1471\" data-end=\"1505\"\u003e\u003cfont style=\"font-size: 14px;\"\u003esystems with frequent load changes\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 data-start=\"1507\" data-end=\"1541\"\u003e\u003cstrong data-start=\"1511\" data-end=\"1541\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAdvanced measurement and analysis\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\u003cul data-start=\"1542\" data-end=\"1796\"\u003e\n\u003cli data-start=\"1542\" data-end=\"1606\"\u003e\n\u003cp data-start=\"1544\" data-end=\"1606\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMeasurement of harmonic voltages and currents up to the \u003cstrong data-start=\"1586\" data-end=\"1604\"\u003e31st harmonic\u003c\/strong\u003e\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1607\" data-end=\"1654\"\u003e\n\u003cp data-start=\"1609\" data-end=\"1654\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMonitoring of total energy (import\/export)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1655\" data-end=\"1695\"\u003e\n\u003cp data-start=\"1657\" data-end=\"1695\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTHD-V and THD-I measurements for each phase\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1696\" data-end=\"1796\"\u003e\n\u003cp data-start=\"1698\" data-end=\"1796\"\u003e\u003cfont style=\"font-size: 14px;\"\u003ePower analysis generation (\u003cstrong data-start=\"1721\" data-end=\"1746\"\u003e20 samples from 9999 min.\u003c\/strong\u003e) - very useful in designing compensation unitsFlexible\u003c\/font\u003e\u003cstrong data-start=\"1802\" data-end=\"1845\" style=\"color: rgb(25, 32, 39); font-family: inherit; font-size: 18px;\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eWiring of compensation elements\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp data-start=\"1846\" data-end=\"1864\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eApplication capabilities:\u003c\/font\u003e\u003c\/p\u003e\u003cul data-start=\"1865\" data-end=\"1977\"\u003e\n\u003cli data-start=\"1865\" data-end=\"1895\"\u003e\n\u003cp data-start=\"1867\" data-end=\"1895\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eSingle-phase capacitors\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1896\" data-end=\"1925\"\u003e\n\u003cp data-start=\"1898\" data-end=\"1925\"\u003e\u003cfont style=\"font-size: 14px;\"\u003etwo-phase capacitors\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1926\" data-end=\"1954\"\u003e\n\u003cp data-start=\"1928\" data-end=\"1954\"\u003e\u003cfont style=\"font-size: 14px;\"\u003ethree-phase capacitors\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1955\" data-end=\"1977\"\u003e\n\u003cp data-start=\"1957\" data-end=\"1977\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eshunt reactors\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 data-start=\"1979\" data-end=\"2013\"\u003e\u003cstrong data-start=\"1983\" data-end=\"2013\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAdjustable time functions\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\u003cp data-start=\"2014\" data-end=\"2029\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eCan be set:\u003c\/font\u003e\u003c\/p\u003e\u003cul data-start=\"2030\" data-end=\"2143\"\u003e\n\u003cli data-start=\"2030\" data-end=\"2045\"\u003e\n\u003cp data-start=\"2032\" data-end=\"2045\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eintervention time\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2046\" data-end=\"2063\"\u003e\n\u003cp data-start=\"2048\" data-end=\"2063\"\u003e\u003cfont style=\"font-size: 14px;\"\u003edischarge time\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2064\" data-end=\"2143\"\u003e\n\u003cp data-start=\"2066\" data-end=\"2143\"\u003e\u003cfont style=\"font-size: 14px;\"\u003esettling time\u003cbr data-start=\"2080\" data-end=\"2083\"\u003eThis allows precise control adjustment depending on the nature of the operation.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 data-start=\"2145\" data-end=\"2170\"\u003e\u003cstrong data-start=\"2149\" data-end=\"2170\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eGenerator functions\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\u003cp data-start=\"2171\" data-end=\"2186\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe regulator has:\u003c\/font\u003e\u003c\/p\u003e\u003cul data-start=\"2187\" data-end=\"2264\"\u003e\n\u003cli data-start=\"2187\" data-end=\"2218\"\u003e\n\u003cp data-start=\"2189\" data-end=\"2218\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eGenerator control input\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2219\" data-end=\"2264\"\u003e\n\u003cp data-start=\"2221\" data-end=\"2264\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eGenerator power compensation function\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 data-start=\"2271\" data-end=\"2316\"\u003e\u003cstrong data-start=\"2274\" data-end=\"2316\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTechnical specifications (brief overview)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\u003cp\u003e\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\u003c\/p\u003e\u003cul data-start=\"2318\" data-end=\"2680\"\u003e\n\u003cli data-start=\"2318\" data-end=\"2356\"\u003e\n\u003cp data-start=\"2320\" data-end=\"2356\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e12 relay compensation outputs\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2357\" data-end=\"2372\"\u003e\n\u003cp data-start=\"2359\" data-end=\"2372\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eSupport for TCR\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2373\" data-end=\"2402\"\u003e\n\u003cp data-start=\"2375\" data-end=\"2402\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e2.9\" graphical LCD display\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2403\" data-end=\"2433\"\u003e\n\u003cp data-start=\"2405\" data-end=\"2433\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAutomatic stage detection\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2434\" data-end=\"2472\"\u003e\n\u003cp data-start=\"2436\" data-end=\"2472\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMeasurement of harmonics up to the 31st order\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2473\" data-end=\"2510\"\u003e\n\u003cp data-start=\"2475\" data-end=\"2510\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eEnergy statistics and history\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2511\" data-end=\"2528\"\u003e\n\u003cp data-start=\"2513\" data-end=\"2528\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTHD-V \/ THD-I\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2529\" data-end=\"2589\"\u003e\n\u003cp data-start=\"2531\" data-end=\"2589\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eSupport for single-phase, two-phase, and three-phase stages\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2590\" data-end=\"2641\"\u003e\n\u003cp data-start=\"2592\" data-end=\"2641\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eProgrammable time for switching off, switching on, and discharging\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2642\" data-end=\"2680\"\u003e\n\u003cp data-start=\"2644\" data-end=\"2680\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eDamage protection in stages\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cul\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":56080503472502,"sku":"RGT-12E","price":220.48,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/4130\/7766\/files\/a1a8c8ce294759ea0cac4554bed17012_a5f797b3-5f7b-4acb-84af-2dd297f46d41.png?v=1754945128"},{"product_id":"rgt-12svc-контролер-на-реактивната-мощност-12-нива-tcr-с-rs485-modbus-rtu","title":"RGT-12SVC - Reactive Power Controller 12 Levels +TCR with RS485 ModBus RTU","description":"\u003cp\u003e\u003cstrong\u003e12 steps + TCR Power Factor Controller with 2.9-inch graphic LCD display and RS-485 (TENSE)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eThe reactive power controller \u003cstrong\u003eRGT-12SVC (TENSE\u003c\/strong\u003e ) is a fully automatic device for optimal switching of compensation steps.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eThe digital processing of the values measured by the regulator ensures high accuracy in assessing the effective voltage, current, and power factor. \u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eThe installation of the device is fully automatic - the regulator determines the size of the individual connected compensation steps by itself. These parameters can also be entered directly manually.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eThe controller switches the compensation steps on and off so that reactive power is regulated with a minimal number of switches. At the same time, the controller accounts for the even load of the individual steps and preferentially switches on those steps that have been disconnected from the power supply for the longest period of time and for which the residual charge is minimal. During the regulation process, the compensation steps are continuously monitored in parallel - faults and changes in values are detected, temporarily removed steps are periodically tested and returned to the regulation process if necessary.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp\u003eGenerator input and generator compensation\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eActivation, discharge, and settling times can be set\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eRemote communication with RS485 (RS485 ModBus RTU)\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eSingle-phase, two-phase, and three-phase capacitors and shunt reactors can be connected\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eHarmonic voltage and current can be monitored up to the 31st harmonic\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eTotal energy (import\/export) can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eTHD-V and THD-I values for each phase can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003ePower analysis creation (20 samples 9999 min.) - for capacitor selection\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":56080503603574,"sku":"RGT-12(SVC)","price":262.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/4130\/7766\/files\/ae4bcd478955332c8f4396aa87708907_18c64829-5110-46b7-a811-72c0f0afc8e5.png?v=1754945131"},{"product_id":"контролер-на-реактивната-мощност-на-12-нива-с-led-екран","title":"12-level reactive power controller with LED display","description":"\u003cp\u003e\u003cstrong\u003e12 Steps Single-Phase Connection Power Factor Controller for Power Factor Management in Networks with Balanced Loads (TENSE)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eThe RGM-12S reactive power control relay is designed to reduce inductive power that is not used by loads but drawn from the network. When inductive reactive power is drawn from the network, it intervenes by activating capacitors of the corresponding value. In this way, it attempts to reach the Cos phi value to the desired level.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp\u003e7 Different programs for power factor compensation\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eManual power factor compensation programs\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eCan only compensate inductive systems\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eAutomatic step measurement\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eDrive, release, and step discharge times are adjustable\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eAdjustable harmonic alarm values for voltage and current\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eAlarm values can be set for overcompensation and undercompensation\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eAlarm output for voltage, harmonic voltage\/current, over and under compensation\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eVoltage, current, and frequency values can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eActive, reactive, and apparent power values can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eUp to the 15th harmonic THD-I can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eUp to the 15th harmonic THD-V can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eCosine value can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003ePower factor value can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eAutomatic fan output\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eEven aging of steps (in some compensation programs)\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":56080503701878,"sku":"RGM-12S","price":168.84,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/4130\/7766\/files\/0764c9ac7c5fc216c12aa893b22e4e13_afb92dc4-43f0-4082-a28f-445cf8228530.webp?v=1754945135"}],"url":"https:\/\/pelek-bg.com\/en\/collections\/regulatori-na-reaktivnata-moshchnost.oembed","provider":"PELEK_BG","version":"1.0","type":"link"}